Skip Navigation
Skip to contents

JPMPH : Journal of Preventive Medicine and Public Health

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
5 "Ground"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Epidemiologic Investigation of an Outbreak of Shigellosis in Kyongju, Korea.
Hyun Sul Lim, Cheol Jung, Geun Ryang Bae, Yeong Joo Hur, Sang Won Lee, Eun Kyeong Jeong
Korean J Prev Med. 2000;33(1):1-9.
  • 2,687 View
  • 38 Download
AbstractAbstract PDF
OBJECTIVES
This study was carried out to investigate the sources of infection and modes of transmission of an outbreak of shigellosis that occurred among pupils of "M" primary school and residents near the school in Kyongju from Sept. 24 to Oct. 24, 1998. METHODS: The subjects who completed a questionnaire and a rectal swab for microbiologic examinations were 1,534 persons (781 males, 753 females), including 469 pupils of "M" primary school (268 males, 201 females). Bacteriological examinations of underground water and simple piped water were done. RESULTS: The attack rate of diarrhea was 28.7% in the subjects from Sept. 24 to Oct. 24, 1998. There was no difference in attack rate of diarrhea by gender, but it was significantly higher in the pupils of "M" primary school than others (p<0.01). The attack rate of diarrhea by resident areas was no different to the pupils of "M" primary school, but was significantly higher in the residents of Mohwa 2 Ri except pupils that "M" primary school is located in (p<0.01). The distribution of date of onset revealed the exposure date to be Sept, 22 and 23 in consideration of incubation periods and common source outbreak followed propagative spread in the epidemic curve. The major characteristics of diarrhea were watery (89.1%) in nature, 1~3 days (72.5%) in duration, 2~3 times (63.9%) in frequency. The clinical symptoms among the diarrheal cases included abdominal pain (74.1%), fever (56.4%), headache (55.9%), chill (40.4%) and tenesmus (31.4%). CONCLUSIONS: The source of infection was estimated to be contaminated underground water and simple piped water caused by leakage from the cess pool. It is highly necessary that the management of drinking water and cess pools should be done thoroughly.
Summary
Health Assessment for Glass Fibre Landfill at Gozan-dong, Inchon.
Soo Hun Cho, Yeong Su Ju, Kyung Ryul Kim, Kang Kun Led, Kug Sun Hong, Hee Chul Eum, Dong Bim Song, Jae Woong Hong, Ho Jang Kwon, Mi Na Ha, Sang Hwan Han, Jpp Heon Seong, Jong Won Kang
Korean J Prev Med. 1997;30(1):77-102.
  • 2,648 View
  • 34 Download
AbstractAbstract PDF
In September 1994, residents of Gozan-dong, Incheon City, made a petition to the government about their health problems which might be caused by previous glass fibre landfill nearby "H" company. In February 1995, at regular academic meeting of occupational and environmental medicine, a research team of "D" University presented that they had found glass fibres in groundwater of the area through their survey. They were suspicious of probable association between ingestion of groundwater contaminated with glass fibres and skin tumors among residents. A joint research team was formed and carried out the survey of environment concerning groundwater and its glass fibre existence, and health assessment of residents in the area and industrial workers of "H" company during May to November, 1995. Analysis of groundwater flow system indicates that the flow lines from the glass fibre landfill pass through or terminate at the 6 houses around the landfill. This means that the groundwater of the 6 houses around the glass fibre landfill could be affected by some possible contaminants from the landfill, but the groundwater quality of the other houses was irrelevant to the landfill. The qualitative and quatitative analyses for glass fibres in 54 groundwater samples including those from the nearby 6 houses, were carried out using SEM equipped with EDS, resulting in no evidence for the presence of glass fibres in the waters. Major precipitates, formed in waters while boiling, were identified as calcium carbonates, in particulary, aragonites in needle form. The results of health assessments of 889 residents in Gozan-dong, participated in this study, showed statistically significant differences in past medical histories of skin tumor and respiratory disease between the exposed group (31 persons who inhabited in 6 houses around the landfill) and the control group, but no significant differences in past medical histories of other diseases, such as cancer mortality, current gastroscopic findings, current skin diseases and respiratory diseases, etc. Also, we could not prove any glass fibres in excised specimens of 9 skin tumors in both groups and there were no health problems possibly associated with glass fibres in employees of the "H" company. After all, we could not authenticate the association, raised by prior investigators, between groundwater streams, assumedly contaminated with glass fibres or not, and specific disease morbidities or common disease/symptom prevalences. That is, we could not find any glass fibres in groundwater as the only exposure factor of this study hypothesis, and there were not enough certain evidences such as increasing disease prevalences, for examples, skin, respiratory and gastrointestinal diseases etc, possibly related to glass fibre exposure, in exposed group. As a matter of course, the conditions for confirming causal association, for example, strength of the association, consistency of the association, specificity of the association, temporality of the association and dose-response relationship etc, have not been satisfied. In conclusion, we were not able to certify the hypothesis that contamination of groundwater with glass fibres might cause any hazardous health effects in human who used it for drinking.
Summary
A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area.
Sung Yong Choi, Deog Hwan Moon, Jong Tae Lee, In Hyuk Song, Cha Eun Lee, Sung Min Lee
Korean J Prev Med. 1994;27(3):505-516.
  • 2,490 View
  • 24 Download
AbstractAbstract PDF
For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of resident, the authors measured the level of SO2, NO2, TSP, CO, CO2 and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows: 1. The mean concentration of CO within the underground shopping center was 3.1+/-1.3ppm in winter and 2.1+/-0.9 ppm in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of C02 within the underground shopping center was 876+/-353 ppm in winter and 757+/-125 ppm in summer. There was a negative correlation (P<0.01) between inner CO2 concentration and air movement in summer and positive correlation (p<0.05) between inner CO2 oncentration and outer CO2 concentration in underground shopping center. 3. The mean concentration SO2 within a underground shopping center was 0.036+/-0.019ppm in winter and 0.040+/-0.013ppm in summer. There was a positive correlation(p<0.01) between inner SO2 concentration and positive correlation between inner SO2 concentration and outer SO2 concentration in summer and winter in Underground shopping center. 4. The mean concentration of NO2 within a underground shopping center was 0.052+/-0.038ppm in winter and 0.042+/-0.016ppm in summer. There was a no correlation between inner NO2 concentration and thermal factors in summer and winter and low correlation between inner NO2 concentration in underground shopping center. 5. The mean concentration of TSP within a underground shopping center was 430+/-214 microgram/m3 in winter, 366+/-73 microgram/m3 in summer, and very in excess of the atmospheric environmental quality standards of Korea(150 microgram/m3). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.
Summary
Assessment of safety of playground equipments in elementary schools in Taegu.
Jung Han Park, Soon Gil Yun
Korean J Prev Med. 1991;24(3):414-427.
  • 2,297 View
  • 19 Download
AbstractAbstract PDF
To assess the safety of playground equipments in the elementary schools of Taegu, a site visit was made to 117 elementary schools out of 119 schools between 1st and 30th April 1991. Safety criteria were developed on the bases of Massachusetts' Playground Safety Check List, standard height of Korean children of 6-12 years old, and source book for designing playground equipments. There were eleven different kinds of playground equipments installed in 117 schools but the number of equipments was about 50-60% of the minimum requirement set by the Ministry of Education except chin-up bar. Among the installed equipments, 47.3% of swings, 16.6% of parallel bars, 20.0% of monkey bars, and 16.0% of slides were broken down. None of the swings, slides, seesaws, monkey bars, and sandboxes met the safety criteria to the full but 59.0 of chin-up bars, 31.4% of parallel bars, and 13.5% of stumps met the criteria fully. The proportions of equipments that were dangerous for children to play on were 26.4% for slides, 20.0% for monkey bars, 11.6% for seesaws, 10.4% for parallel bars, 9.85 for sandboxes, 7.4% for swings and stumps, and 3.9% for chin-up bars. The rests were either in need of repair of broken down. It was revealed by this survey that the playground equipments were too short in number to meet the minimum requirement, designs and size were not standardized, and many of the equipments were involved with the risk of child accidents. Therefore, a safety standard for the playground equipments should be developed and the existing equipments should be repaired immediately.
Summary
English Abstract
Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations.
Ki Youn Ki, Jae Beom Park, Chi Nyon Kim, Kyung Jong Lee
J Prev Med Public Health. 2006;39(4):325-330.
  • 2,680 View
  • 77 Download
AbstractAbstract PDF
OBJECTIVES
The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. METHODS: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. RESULTS: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, PM10 and PM2.5, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean PM10 and PM2.5 concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). CONCLUSIONS: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.
Summary

JPMPH : Journal of Preventive Medicine and Public Health
TOP