Search
- Page Path
-
HOME
> Search
Original Articles
- Epidemiologic Investigation of an Outbreak of Shigellosis in Kyongju, Korea.
-
Hyun Sul Lim, Cheol Jung, Geun Ryang Bae, Yeong Joo Hur, Sang Won Lee, Eun Kyeong Jeong
-
Korean J Prev Med. 2000;33(1):1-9.
-
-
-
Abstract
PDF
- OBJECTIVES
This study was carried out to investigate the sources of infection and modes of transmission of an outbreak of shigellosis that occurred among pupils of "M" primary school and residents near the school in Kyongju from Sept. 24 to Oct. 24, 1998. METHODS: The subjects who completed a questionnaire and a rectal swab for microbiologic examinations were 1,534 persons (781 males, 753 females), including 469 pupils of "M" primary school (268 males, 201 females). Bacteriological examinations of underground water and simple piped water were done. RESULTS: The attack rate of diarrhea was 28.7% in the subjects from Sept. 24 to Oct. 24, 1998. There was no difference in attack rate of diarrhea by gender, but it was significantly higher in the pupils of "M" primary school than others (p<0.01). The attack rate of diarrhea by resident areas was no different to the pupils of "M" primary school, but was significantly higher in the residents of Mohwa 2 Ri except pupils that "M" primary school is located in (p<0.01). The distribution of date of onset revealed the exposure date to be Sept, 22 and 23 in consideration of incubation periods and common source outbreak followed propagative spread in the epidemic curve. The major characteristics of diarrhea were watery (89.1%) in nature, 1~3 days (72.5%) in duration, 2~3 times (63.9%) in frequency. The clinical symptoms among the diarrheal cases included abdominal pain (74.1%), fever (56.4%), headache (55.9%), chill (40.4%) and tenesmus (31.4%). CONCLUSIONS: The source of infection was estimated to be contaminated underground water and simple piped water caused by leakage from the cess pool. It is highly necessary that the management of drinking water and cess pools should be done thoroughly.
-
Summary
- A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area.
-
Sung Yong Choi, Deog Hwan Moon, Jong Tae Lee, In Hyuk Song, Cha Eun Lee, Sung Min Lee
-
Korean J Prev Med. 1994;27(3):505-516.
-
-
-
Abstract
PDF
- For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of resident, the authors measured the level of SO2, NO2, TSP, CO, CO2 and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows: 1. The mean concentration of CO within the underground shopping center was 3.1+/-1.3ppm in winter and 2.1+/-0.9 ppm in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of C02 within the underground shopping center was 876+/-353 ppm in winter and 757+/-125 ppm in summer. There was a negative correlation (P<0.01) between inner CO2 concentration and air movement in summer and positive correlation (p<0.05) between inner CO2 oncentration and outer CO2 concentration in underground shopping center. 3. The mean concentration SO2 within a underground shopping center was 0.036+/-0.019ppm in winter and 0.040+/-0.013ppm in summer. There was a positive correlation(p<0.01) between inner SO2 concentration and positive correlation between inner SO2 concentration and outer SO2 concentration in summer and winter in Underground shopping center. 4. The mean concentration of NO2 within a underground shopping center was 0.052+/-0.038ppm in winter and 0.042+/-0.016ppm in summer. There was a no correlation between inner NO2 concentration and thermal factors in summer and winter and low correlation between inner NO2 concentration in underground shopping center. 5. The mean concentration of TSP within a underground shopping center was 430+/-214 microgram/m3 in winter, 366+/-73 microgram/m3 in summer, and very in excess of the atmospheric environmental quality standards of Korea(150 microgram/m3). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.
-
Summary
English Abstract
- Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations.
-
Ki Youn Ki, Jae Beom Park, Chi Nyon Kim, Kyung Jong Lee
-
J Prev Med Public Health. 2006;39(4):325-330.
-
-
-
Abstract
PDF
- OBJECTIVES
The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. METHODS: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. RESULTS: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, PM10 and PM2.5, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean PM10 and PM2.5 concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). CONCLUSIONS: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.
-
Summary
TOP